. 2018 Jan 30;9:29. doi: 10.3389/fphys.2018.00029

Figure 8.

Figure 8

Influence of the type of surface sensor (absolute mean difference and 95% limits of agreement). Al, aluminium; env, environment; LoA, limits of agreement; NA, not applicable; PRT, platinum resistance thermometer; TC, thermocouple; thermom, thermometer. Filled squares indicate mean and open circles indicate the range (minimum and maximum values). Dashed vertical lines indicate the thresholds for guiding practical significance. aFrom the forest plots in the Supplementary Material; mean differences are presented here as absolute values, indicative of magnitude but not relative direction. bNot presented here due to the limited information reported in original article; see text for information. cData from all attachment types (aluminium, Fixomull, Tegaderm, and Micropore tapes) and environments (15–35°C, 0.5 m/s) are pooled here.